Three Phase 500 psi WP Separator

The 500 psi WP three phase separator is designed to handle flowing or artificially lifted well capacities of

  • 2000-3000 BPD water
  • 2000-3000 BPD oil
  • 10 MMSCFD (0.3 million m3 per day) of gas

and is mounted on a double axle trailer. The vessel is a 42" X 12' seam-to-seam horizontal unit built in accordance with ASME Code Section VIII and conforms to the material requirements outlined in NACE MR-01-75 Revision 80. Three Phase 500 psi WP SeparatorThe unit has a 2"-3000 psi WP inlet manifold with by-pass, 2" or 3" Mock or Floco positive displacement liquid meter with a proportional-to-flow sampler, 2" liquid level control valve, 3" Daniel Senior gas orifice meter with an Barton gas flow recorder, and a 2" back pressure regulator. The unit is supplied with an extra hammer union, two 2" X 10'-1100 psi WP hoses, calibrated sample container, clock key, orifice crank, complete set of orifice plates.